Inline sterile filter for inflow pipes of water-injected medical devices

With the i3 FIVE inline sterile filter, we offer the optimal solution for all areas where a safe microfiltration of all waterborne pathogens is needed for high water flows. This may be, for instance, in the automatic reprocessing of medical devices (e.g. endoscopes) and for filling birthing tubs. The i3 FIVE inline filter provides sterile filtration of tap water and is installed to protect against contamination caused by waterborne pathogens, such as Legionella pneumophilaPseudomonas aeruginosa or microbes, in the inflow pipes of devices and instruments.

The reprocessing of medical devices can take place manually, partly automatically or fully automatically. The i3 FIVE inline filter can be used for partly and fully automatic reprocessing thanks to the use of cleaning and disinfecting devices. The filter is installed in the inflow pipe of the reprocessing machine and serves as a safe barrier against all waterborne microbes during the pre-cleaning and final rinsing stages.

The pre-cleaning involves the processing of successful disinfection. In this reprocessing phase, contaminants and cleaning solutions which could remain on the medical device are rinsed away using tap water. During pre-cleaning, microfiltration is recommended to prevent contamination of the device, which could be caused by waterborne pathogens.

The final rinsing must be carried out using microbiologically pure water of drinking water quality to ensure that no new microorganisms are introduced into the endoscope after all the remaining disinfectant has been rinsed out. Medical device manufacturers (e.g. of endoscopes) stipulate the use of demineralised (purified) or distilled water for the final rinse. However, because both are frequently contaminated with microorganisms, a sterile filtration for both should be carried out to ensure successful reprocessing.

Features

  • Sterile filtration acc. to ASTM F838

  • 50 days' operation time (7 weeks)

  • Microfiltration 0.2 μm

  • Wipe disinfectable filter surface

  • High and stable flow rate over the entire duration of use

  • Clear product identification for a legally conform documentation of the filter change using the i3 trackApp or i3 change service

  • Versatile applications
    (e.g. for the filling of birthing tubs, endoscope washing machines)

  • Safe and easy connection by means of a quick release coupling

  • The water filter provides lasting protection against waterborne pathogens for immunocompromised and immunosuppressed patients